Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Opt Express ; 31(22): 36188-36201, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-38017773

RESUMO

In digital holographic microscopy, aberrations caused by imperfect optical system settings can greatly affect the quantitative measurement of the target phase, so the compensation of aberrations in the distorted phase has become a key point of research in digital holographic microscopy. Here, we propose a fully automatic numerical phase aberration compensation method with fast computational speed and high robustness. The method uses bicubic downsampling to smooth the sample phase for reducing its disturbance to the background aberration fit, while reducing the computational effort of aberration compensation. Polynomial coefficients of the aberration fitting are iteratively optimized in the process of minimizing the global phase gradient by improving the phase gradient operator and constructing the loss function to achieve accurate fitting of the phase aberration. Simulation and experimental results show that the proposed method can achieve high aberration compensation accuracy without prior knowledge of the hologram recording settings or manual selection of the background area free of samples, and it is suitable for samples with moderate and relatively flat background area, which can be widely used in the quantitative analysis of biological tissues and micro and nano structures.

2.
Opt Express ; 30(13): 23511-23530, 2022 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-36225029

RESUMO

We proposed a calibration method for high-precision zoom lenses of optical measurement machines based on Fully Connected Neural Network (FNN), using a 5-layer neural network instead of a camera calibration model, to achieve continuous calibration of zoom lenses at any zoom setting by calibrating typical zooms. From the experimental verification, the average calibration error of this method is 9.83×10-4mm and the average measurement error at any zoom setting is 0.01317mm. The overall calibration precision is better than that of Zhang's calibration method and can meet the application requirements of a high-precision optical measurement machine. The method proposed in this paper provided a new solution and a new idea for the calibration of zoom lenses, which can be widely used in the fields of precision parts inspection and machine-vision measurement.


Assuntos
Lentes , Calibragem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...